RVFV-K Cable
RVFV-K Cable
Flexible Power Cable 0.6/1kvV with Double Steel Tape Armoured Voltage Rating: 600/1000 Volts Conductor: plain copper conductor, class 5 Insulation: Cross-linked polyethylene (XLPE) Installation conditions: Open Air. Buried. In conduit. Over sheath: Flexible PVC Armour: Double steel or aluminium tape armour
+8613290249713
+8613290249713
irisqi0722@gmail.com
Contact Us

Product Advantages

RVFV-K Cable Application

RVFV-K cable is especially suitable for fixed installations that may be subject to mechanical aggression. It is highly recommended for use in installations where the presence of rodents could imply a threat to the cable (such as warehouses, production plants and agricultural facilities). At the same time, its use is recommended for street lighting installations.
CONSTRUCTION :

RVFV-K Cable Construction


n2xby-cable-structure

Conductor: Electrolytic annealed copper conductor, class 5 (flexible) according to EN 60228 and IEC 60228.
Insulation: Cross-linked polyethylene (XLPE) insulation type XLPE according to IEC 60502-1.
Armour bedding: Black extruded PVC separation sheath.
Armour: Double steel or aluminium tape armour. Aluminium armour is used in single-core cables to avoid parasite currents that may overheat the cable. Steel tape is used in the multicore cables.
Outer sheath: Flexible PVC outer sheath, Black colour.

The standard identification of insulated conductors is the following:
1 x Natural
2 x Blue + Brown
3 G Blue + Brown + Green/Yellow
3 x Brown + Black + Grey
3 x + 1 x Brown + Black + Grey + Blue (reduced cross-section)
4 G Brown + Black + Grey + Green/Yellow
4 x Brown + Black + Grey + Blue
5 G Brown + Black + Grey + Blue + Green/Yellow
6 or more Black numbered + Green/Yellow
CHARACTERISTICS :

RVFV-K Cable Characteristics

Electrical performance: Low voltage 0,6/1kV.
Thermal performance:
Maximum service temperature: 90ºC.
Maximum short-circuit temperature: 250ºC (max. 5 s).
Minimum service temperature: -40ºC (fixed and protected installations).
Fire performance:
Flame non-propagation according to EN 60332-1 and IEC 60332-1.
Reduced halogen emission. Chlorine <15%.
Reaction to fire CPR: Eca, according to EN 50575.
Mechanical performance:
Minimum bending radius: x5 cable diameter.
Impact resistance: AG2 Medium severity.
Environmental performance
Chemical & Oil resistance: Good.
UV Resistant: UNE 211605.
Installation conditions
Open Air.
Buried.
In conduit.
Other
Meter by meter marking.
PARAMETER :

RVFV-K Cable Dimensions

Cross sectionDiameterWeightOpen air 30ºCBuried 20ºCVoltage drop
(mm2)(mm)(kg/km)(A)(A)(V/A.km)
1x1614,4370101792,55
1x25164851351011,61
1x3517,15951691221,16
1x5018,67302071440,86
1x7020,39602681780,594
1x9522,412553282110,428
1x12024,415103832400,339
1x15026,31814442710,275
1x18528,322155103040,22
1x24031,328056073510,167
1x3003434207033960,133
2x1,512,3225262631
2x2,513,2270363419
2x414,1320494411,8
2x615,742063567,88
2x1017,153086734,68
2x1618,6690115952,94
3x1,512,8255232226,8
3x2,513,8300322916,4
3x415,1380423710,2
3x616,448554466,83
3x1017,863075614,06
3x1619,6845100792,55
3x2523,912701271011,61
3x3526,216301581221,16
3x5029,821051921440,86
3x7033,327552461780,594
3x9540,139602982110,428
3x16+1x10--100792,55
3x25+1x162513551271011,61
3x35+1x1627,316951581221,16
3x50+1x2531,523151921440,86
3x70+1x353631202461780,594
3x95+1x5041,644252982110,428
3x120+1x7046,858953462400,339
3x150+1x7051,570053992710,275
3x185+1x9556,587304563040,22
3x240+1x12063,4110405383510,167
3x300+1x15070,2129056213960,133
4x1,513,8290232226,8
4x2,514,7350322916,4
4x416435423710,2
4x617,454054466,83
4x1019,675075614,06
4x1621,81020100792,55
4x2526,314901271011,61
4x3529,119651581221,16
4x5033,726451921440,86
4x7039,439102461780,594
4x954349002982110,428
5G1,514,7330232226,8
5G2,515,7400322916,4
5G417,2505423710,2
5G618,763054466,83
5G1021,491075614,06
5G1624,11255100792,55
5G2528,317901271011,61
5G3531,523551581221,16
5G5037,132551921440,86
5G7042,547252461780,594
5G9547,960652982110,428
5G12053,575803462400,339
5G15059,593003992710,275
6G1,514,3325262633,9
6G2,515,9420363420,4
6G417,5540494411,9
7G1,514,1335262633,9
7G2,515,6430363420,4
7G417,3565494411,9
10G1,516,4435262633,9
10G2,517,7555363420,4
12G1,517,1480262633,9
12G2,519,4645363420,4
12G422,4880494411,9
14G1,518,6545262633,9
14G2,520,8725363420,4
16G1,519,3600262633,9
16G2,521,3785363420,4
19G1,520660262633,9
19G2,522,5890363420,4
19G425,91230494411,9
24G1,522775262633,9
24G2,524,51045363420,4
24G4301510494411,9
27G1,523,4850262633,9
27G2,5271170363420,4
37G1,525,91065262633,9
37G2,529,41465---
61G1,536,92285262633,9

Product Display

拼图_美图设计室

Qualification Certificate

  • 润邦线缆有限公司-智能制造管理体系认证证书-1
  • 润邦线缆有限公司-碳足迹认证证书
  • 润邦线缆有限公司-绿色设计产品管理体系认证证书-1
  • 润邦线缆有限公司-绿色供应链管理体系认证证书-1
  • 润邦线缆有限公司-绿色工厂认证证书-1
  • 润邦线缆2026.06.01一种可清障的高压架空线
  • 润邦2023208745394一种多芯分支组合电缆
  • 润邦2022228563977一种变电站电力输送用电缆

Factory Showcase

  • Z01231
  • Z01238
  • Z01237
  • Z01236
  • Z01233
  • DSC09918

FAQ

01 — What specifications are available for this cable?

We offer different conductor sizes, insulation materials, voltage ratings, core configurations and other specifications according to product type and application requirements. Please contact us for the detailed product specification sheet.

 

02 — Can this cable be customized?

Yes. Cable specifications can be customized based on your application, installation environment and project requirements. Our team can assist with conductor size, insulation, sheath, voltage rating, color, length and other requirements.

 

03 — What standards does this cable comply with?

Our cable products can be manufactured according to applicable international and regional standards depending on the product and customer requirements. Please confirm the required standard with our sales team before placing an order.


04 — Can you provide samples before bulk orders?

Yes. Samples may be available for evaluation depending on the product type and specifications. Please contact us with your required model and specifications so we can confirm sample availability.

 

05 — What is the minimum order quantity?

MOQ depends on the cable type, specifications and production requirements. Please contact us with your required quantity and specifications for a specific quotation.

 

06 — How long is the production lead time?

Production lead time depends on product specifications, order quantity and current production schedules. We will confirm the estimated delivery time when providing the quotation.

Contact Us

Submit

Related products

DC001

DC001

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC003

DC003

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC004

DC004

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC005

DC005

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC006

DC006

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC0011

DC0011

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC0013

DC0013

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC0018

DC0018

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

High Voltage Cable

High Voltage Cable

High voltage cables suitable for a variety of applications, from powering homes and businesses to large-scale industrial operations. Knowing how these cables work and understanding their various components is essential for anyone looking to install or maintain them.

YSLY Control Cable

YSLY Control Cable

PVC Insualted Control Cable Voltage Rating: 300/500V Conductor: soft annealed copper,class 5 Insulation: PVC Sheath: PVC

Solar Cables

Solar Cables

Widely used for electrical installation of indoor and outdoor solar energy equipment.

6 / 20