NYBY / HFG Cable
NYBY / HFG Cable
Low Voltage Copper PVC Cable with Double Galvanized Steel Tape Armoured Conductor: Copper Insulation: PVC Armour: Double galvanized steel tape Sheath: Polyvinylchloride compound PVC 5V-90 Voltage : 0.6/1kV Package : Export wooden drum & iron wooden drum or as customer require
+8613290249713
+8613290249713
irisqi0722@gmail.com
Contact Us

Product Advantages

Cable Application:

NYBY HFG cable is suitable for AC 50Hz power and distribution lines with rated voltage of 0.6/1kV, which can be used in fixed industrial power applications, underground tunnels, etc. Using steel wire armour offers great mechanical protection, making it rigid with a large radius.

Cable Standards:

IEC 60228 Conductors
IEC 60502-1 Power cables with extruded insulation and their accessories for rated voltages from 1kV(Um=1.2kV) up to 30kV(Um=36kV) - Part 1: Cables for rated voltages of 1 kV(Um=1.2kV) and 3 kV(Um=3.6kV)
CONSTRUCTION :

Cable Construction

n2xby cable structure

Conductor: Copper  Class 1: solid conductor, or Class 2: stranded conductor
Insulation: Polyvinyl chloride PVC

Filler: Non-hygroscopic material
Binder tape: Non-hygroscopic material
Inner sheath: Polyvinyl chloride PVC
Armour: Double galvanized steel tape
Outer sheath: Polyvinyl chloride PVC
TECHNICAL :
Voltage Rating Uo/U (Um) 0.6/1 (1.2)kV
Nominal Voltage DC (core-earth/core-core) :1.8/1.8kV
Test Voltage:4kV
Temperature Rating:
Flexed: 5°C to +70°C
Fixed: -35°C to +70°C
Maximum Short Circuit Temperature:
+160°C (max 5 seconds)
Minimum Bend Radius:
Single core: 15 x overall diameter
Multi core: 12 x overall diameter
PARAMETER :

Cable Parameter:

0.6/1kV-1 core copper conductor PVC insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.
weight
Max.D.C resistance of conductor(20℃)Current carrying capacity
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
1X101.00.21.812.42901.835070
1X161.00.21.813.53711.156692
1X251.20.21.815.24890.72785115
1X351.20.21.815.85950.524105140
1X501.40.21.817.57530.387125175
1X701.40.21.819.19740.268160205
1X951.60.21.821.112600.193195250
1X1201.60.21.822.515220.153235290
1X1501.80.21.824.518580.124265325
1X1852.00.21.826.422300.0991300365
1X2402.20.21.929.228350.0754355420
1X3002.40.21.932.034810.0601410475
1X4002.60.52.137.348480.047480540
1X5002.80.52.241.560560.0366550610
1X6302.80.52.345.174060.0283645735
0.6/1kV-2 core copper conductor PVC insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.
weight
Max.D.C resistance of conductor(20℃)Current carrying capacity
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
2X2.50.80.21.813.52497.41--
2X410.21.815.33624.61--
2X610.21.816.34273.08--
2X1010.21.819.05721.8350-
2X1610.21.821.27491.1566-
2X251.20.21.824.510120.72785-
2X351.20.21.825.812350.524105105
2X501.40.21.929.315940.387125125
2X701.40.22.032.720890.268160155
2X951.60.52.138.931700.193195185
2X1201.60.52.241.937930.153235215
2X1501.80.52.445.946020.124265235
2X18520.52.550.655690.0991300265
0.6/1kV-3 core copper conductor PVC insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.
weight
Max.D.C resistance of conductor(20℃)Current carrying capacity
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
3X2.50.80.21.814.33237.41--
3X41.00.21.816.14224.61--
3X61.00.21.817.35093.08--
3X101.00.21.819.96981.835070
3X161.00.21.822.39351.156692
3X251.20.21.825.912840.72785115
3X351.20.21.827.215990.524105140
3X501.40.21.931.120930.387125175
3X701.40.22.035.228170.268160205
3X951.60.52.241.341410.193195250
3X1201.60.52.344.650030.153235290
3X1501.80.52.549.461670.124265325
3X18520.52.654.074260.0991300365
3X2402.20.52.860.694800.0754355420
3X3002.40.53.066.4115840.0601410475
0.6/1kV-4 core copper conductor PVC insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.
weight
Max.D.C resistance of conductor(20℃)Current carrying capacity
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
4X2.50.80.21.814.93827.41--
4X410.21.817.24974.61--
4X610.21.818.56073.08--
4X1010.21.821.58481.835070
4X1610.21.824.111481.156692
4X251.20.21.828.115900.72785115
4X351.20.21.929.820180.524105140
4X501.40.22.034.626900.387125175
4X701.40.52.240.039800.268160205
4X951.60.52.445.452300.193195250
4X1201.60.52.549.564030.153235290
4X1501.80.52.654.478480.124265325
4X18520.52.860.095450.0991300365
4X2402.20.53.066.9121400.0754355420
4X3002.40.53.273.4148810.0601410475
0.6/1kV-5 core copper conductor PVC insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.
weight
Max.D.C resistance of conductor(20℃)Current carrying capacity
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
5X2.50.80.21.816.14357.41--
5X410.21.818.45854.61--
5X610.21.819.97133.08--
5X1010.21.823.210131.835070
5X1610.21.826.213721.156692
5X251.20.21.930.819260.72785115
5X351.20.22.032.724560.524105140
5X501.40.52.239.336640.387125175
5X701.40.52.343.948260.268160205
5X951.60.52.550.464230.193195250
5X1201.60.52.654.478130.153235290
5X1501.80.52.860.396650.124265325
5X18520.53.066.1116920.0991300365
5X2402.20.53.373.9149090.0754355420
5X3002.40.53.581.5183940.0601410475
0.6/1kV-3+1 core copper conductor PVC insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.
weight
Max.D.C resistance of conductor(20℃)Current carrying capacity
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
3*4+1*2.51.0/0.80.21.816.76674.61/7.41--
3*6+1*41.0/1.00.21.818.25813.08/4.61--
3*10+1*61.0/1.00.21.820.87871.83/3.085070
3*16+1*101.0/1.00.21.823.510741.15/1.836692
3*25+1*161.2/1.00.21.827.214970.727/1.1585115
3*35+1*161.2/1.00.21.828.417950.524/1.15105140
3*50+1*251.4/1.20.22.032.823960.387/0.727125175
3*70+1*351.4/1.20.52.138.035840.268/0.524160205
3*95+1*501.6/1.40.52.343.046690.193/0.387195250
3*120+1*701.6/1.40.52.447.358250.153/0.268235290
3*150+1*701.8/1.40.52.551.068040.124/0.268265325
3*185+1*952.0/1.60.52.756.284300.0991/0.193300365
3*240+1*1202.2/1.60.52.962.7107010.0754/0.153355420
3*300+1*1502.4/1.80.53.168.9131150.0601/0.124410475
0.6/1kV-4+1 core copper conductor PVC insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.
weight
Max.D.C resistance of conductor(20℃)Current carrying capacity
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
4*4+1*2.51.0/0.80.21.818.05454.61/7.41--
4*6+1*41.0/1.00.21.819.66833.08/4.61--
4*10+1*61.0/1.00.21.822.59411.83/3.085070
4*16+1*101.0/1.00.21.825.612951.15/1.836692
4*25+1*161.2/1.00.21.829.818270.727/1.1585115
4*35+1*161.2/1.00.21.931.422310.524/1.15105140
4*50+1*251.4/1.20.52.137.933830.387/0.727125175
4*70+1*351.4/1.20.52.242.044320.268/0.524160205
4*95+1*501.6/1.40.52.448.359190.193/0.387195250
4*120+1*701.6/1.40.52.652.472320.153/0.268235290
4*150+1*701.8/1.40.52.756.885240.124/0.268265325
4*185+1*952.0/1.60.52.963.0106330.0991/0.193300365
4*240+1*1202.2/1.60.53.170.1134630.0754/0.153355420
4*300+1*1502.4/1.80.53.477.3165820.0601/0.124410475
0.6/1kV-3+2 core copper conductor PVC insulated steel tape armored PVC sheathed power cable
Nominal cross sectional areaInsulation thicknessNon-magnetic steel tape thickness Sheath thicknessApproximate outer diameterApprox.
weight
Max.D.C resistance of conductor(20℃)Current carrying capacity
mm2mmmmmmmmkg/kmΩ/kmIn Air(A)In Ground(A)
3*4+2*2.51.0/0.80.21.817.55174.61/7.41--
3*6+2*41.0/1.00.21.819.36573.08/4.61--
3*10+2*61.0/1.00.21.821.88841.83/3.085070
3*16+2*101.0/1.00.21.825.012231.15/1.836692
3*25+2*161.2/1.00.21.928.917180.727/1.1585115
3*35+2*161.2/1.00.21.930.020170.524/1.15105140
3*50+2*251.4/1.20.22.135.627740.387/0.727125175
3*70+2*351.4/1.20.52.340.240400.268/0.524160205
3*95+2*501.6/1.40.52.445.853290.193/0.387195250
3*120+2*701.6/1.40.52.650.566660.153/0.268235290
3*150+2*701.8/1.40.52.753.876290.124/0.268265325
3*185+2*952.0/1.60.52.960.296300.0991/0.193300365
3*240+2*1202.2/1.60.53.166.4120880.0754/0.153355420
3*300+2*1502.4/1.80.53.373.0147540.0601/0.124410475

Product Display

拼图_美图设计室

Qualification Certificate

  • 润邦线缆有限公司-智能制造管理体系认证证书-1
  • 润邦线缆有限公司-碳足迹认证证书
  • 润邦线缆有限公司-绿色设计产品管理体系认证证书-1
  • 润邦线缆有限公司-绿色供应链管理体系认证证书-1
  • 润邦线缆有限公司-绿色工厂认证证书-1
  • 润邦线缆2026.06.01一种可清障的高压架空线
  • 润邦2023208745394一种多芯分支组合电缆
  • 润邦2022228563977一种变电站电力输送用电缆

Factory Showcase

  • Z01231
  • Z01238
  • Z01237
  • Z01236
  • Z01233
  • DSC09918

FAQ

01 — What specifications are available for this cable?

We offer different conductor sizes, insulation materials, voltage ratings, core configurations and other specifications according to product type and application requirements. Please contact us for the detailed product specification sheet.

 

02 — Can this cable be customized?

Yes. Cable specifications can be customized based on your application, installation environment and project requirements. Our team can assist with conductor size, insulation, sheath, voltage rating, color, length and other requirements.

 

03 — What standards does this cable comply with?

Our cable products can be manufactured according to applicable international and regional standards depending on the product and customer requirements. Please confirm the required standard with our sales team before placing an order.


04 — Can you provide samples before bulk orders?

Yes. Samples may be available for evaluation depending on the product type and specifications. Please contact us with your required model and specifications so we can confirm sample availability.

 

05 — What is the minimum order quantity?

MOQ depends on the cable type, specifications and production requirements. Please contact us with your required quantity and specifications for a specific quotation.

 

06 — How long is the production lead time?

Production lead time depends on product specifications, order quantity and current production schedules. We will confirm the estimated delivery time when providing the quotation.

Contact Us

Submit

Related products

DC001

DC001

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC003

DC003

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC004

DC004

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC005

DC005

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC006

DC006

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC0011

DC0011

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC0013

DC0013

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC0018

DC0018

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

High Voltage Cable

High Voltage Cable

High voltage cables suitable for a variety of applications, from powering homes and businesses to large-scale industrial operations. Knowing how these cables work and understanding their various components is essential for anyone looking to install or maintain them.

YSLY Control Cable

YSLY Control Cable

PVC Insualted Control Cable Voltage Rating: 300/500V Conductor: soft annealed copper,class 5 Insulation: PVC Sheath: PVC

Solar Cables

Solar Cables

Widely used for electrical installation of indoor and outdoor solar energy equipment.

6 / 20