ACAR-Aluminum Conductor Alloy Reinforced
ACAR-Aluminum Conductor Alloy Reinforced
Aluminium Conductor Alloy Reinforced (ACAR) is formed by concentrically stranded wires of Aluminium on high strength Aluminium -Magnesium -Silicon(Al Mg Si) alloy core.
+8613290249713
+8613290249713
irisqi0722@gmail.com
Contact Us

Product Advantages

APPLICATION

Used as bare overhead transmission cable and as primary and secondary distribution cable. A good strength-to-weight ratio makes ACAR applicable where both ampacity and strength are prime considerations in line design; for equal weight, ACAR offers higher strength and ampacity than ACSR.

DESCRIPTION

Aluminium Conductor Alloy Reinforced (ACAR) is formed by concentrically stranded wires of Aluminium on high strength Aluminium -Magnesium -Silicon(Al Mg Si) alloy core. 

SPECIFICATIONS

• IEC 61089 Round wire concentric lay overhead electrical stranded conductors

• ASTM B 524 Concentric-Lay-Stranded Aluminum Conductors, Aluminum-Alloy Reinforced (ACAR, 1350/6201)

• GB 1179 Round wire concentric lay overhead electrical stranded conductors

ACAR/A1/A2

Code
Number
DiameterNo.of
Wires
AreasLinear MassRated
Strength
D.C.
Resistance
WireCondA1A2A1A2Total
mmmmNo.No.mm²mm²mm²kg/kmkNΩ/km
161.765.28439.737.3017.046.63.851.7896
252.206.604315.211.426.672.85.931.1453
402.788.354324.318.342.6116.59.250.7158
633.4910.54338.328.767.1183.514.380.4545
1004.4013.24360.845.6106291.222.520.2863
1252.9714.912783.348.6132362.727.790.2302
1603.3616.812710762.2169464.235.040.1798
2003.7618.812713377.8211580.343.130.1439
2504.2121.012716797.2264725.353.920.1151
2503.0421.31819131138269742.260.390.1154
3153.3423.430726361.3324892.660.520.0916
3153.4223.91819165174339935.176.090.0916
4003.7626.330733477.84111133.575.190.0721
4003.8527.018192102214311187.595.580.0721
4503.9927.930737587.64631275.284.590.0641
4504.0828.618192362494851335.9107.520.0641
5004.2129.430741797.35141416.993.980.0577
5004.3130.118192622775391484.3119.470.0577
5604.4531.23074671095761586.9105.260.0515
5603.4531.054750465.45701571.9101.540.0516
6303.7133.442194542056601820.0130.250.0458
6303.7934.124372714176881897.5160.190.0458
7103.9435.542195122327432051.2146.780.0407
7104.0236.224373054707752138.4180.530.0407
8004.1837.642195772618382311.2165.390.0361
8004.2738.424373445308732409.5203.410.0361
9004.4339.942196492949422600.1186.060.0321
9003.6640.254375673889552638.4199.540.0321
10003.8041.8721981621510322849.1190.940.0289
10003.8542.4543763043210612931.6221.710.0289
11204.0244.2721991424111553191.0213.850.0258
11204.0844.9543770548311893283.4248.320.0258
12504.2546.77219102026912893561.4238.680.0231
12504.3147.4543778753913273664.5277.140.0231
14004.5049.47219114330214443988.8267.320.0207


ACAR/A1/A3

Code
Number
DiameterNo.of
wires
AreasLinear massRated
strength
D.C.
resistance
WireCondA1A2A1A2Total
mmmm

mm²mm²mm²kg/kmkNΩ/km
161.765.29439.787.3317.146.84.071.7896
252.216.624315.311.526.773.16.291.1453
402.798.374324.418.342.8117.09.820.7158
633.5010.54338.528.967.4184.314.800.4545
1004.4113.24361.145.8107292.523.490.2863
1252.9814.912783.748.8132364.129.290.2302
1603.3716.912710762.5170466.036.950.1798
2003.7718.812713478.1212582.544.780.1439
2504.2121.112716797.6265728.155.980.1151
2503.0521.41819132139271746.064.670.1154
3153.3423.430726361.4325894.462.400.0916
3153.4324.01819166175341940.081.480.0916
4003.7726.430733478.04121135.876.820.0721
4003.8627.018192112224331193.7100.300.0721
4503.9928.030737687.74641277.886.420.0641
4504.1028.718192372504871342.9112.840.0641
5004.2129.530741897.55151419.896.030.0577
5004.3230.218192632785421492.1125.380.0577
5604.4631.23074681095771590.1107.550.0515
5603.4531.154750565.55701573.9103.530.0516
6303.7233.442194562066621826.0134.590.0458
6303.8034.224372724206921909.0169.140.0458
7103.9535.542195142327462057.8151.680.0407
7104.0336.324373074737802151.4190.610.0407
8004.1937.742195792628402318.7170.900.0361
8004.2838.524373465338792424.2214.780.0361
9004.4440.042196512949452608.5192.270.0321
9003.6640.354375693909592649.5207.790.0321
10003.8041.8721981821610342855.4195.470.0289
10003.8642.5543763243310662943.9230.880.0289
11204.0244.3721991624211583198.1218.920.0258
11204.0945.0543770848511943297.2258.580.0258
12504.2546.87219102227012923569.3244.330.0231
12504.3247.5543779154213323679.9288.600.0231
14004.5049.57219114530214473997.6273.650.0207

ACAR

Conductor SizeNo. and Diameter of WiresNominal Outside DiameterMass per Unit LengthRated
strength
Nominal DC Resistance at 20℃
MCM(AWG)mm²AluminiumAlloy
No.mmNo.mmmmkg/kmKNΩ/km
30.5815.541.67931.6795.0342.63.671.9783
41.74(4)21.241.96131.9615.8958.04.971.4503
48.6924.742.11832.1186.3567.85.761.2432
66.36(2)33.642.47432.4747.4292.47.790.9112
77.4739.342.67232.6728.031088.940.7811
105.6(1/0)53.543.11933.1199.3514712.00.5733
123.362.543.37133.37110.1117113.650.4908
133.1(2/0)67.443.50333.50310.5218514.70.4545
155.478.743.78533.78511.3521617.10.3893
167.8(3/0)85.043.93233.93211.8023418.30.3607
195.799.144.24734.24712.7427221.30.3092
211.6(4/0)10744.41734.41713.2529423.00.2859
246.912544.77034.77014.3134426.90.2451
250127152.91342.91314.5634824.40.2346
250127122.91372.91314.5634827.60.2400
300152153.19343.19315.9641828.90.1952
300152123.19373.19315.9641832.80.1998
350177153.44743.44717.2448733.20.1675
350177123.44773.44717.2448737.40.1714
400203153.68543.68518.4255737.50.1466
400203123.68573.68518.4255642.40.1500
450228153.90943.90919.5462741.60.1303
450228123.90973.90919.5462647.20.1333
500253154.12044.12020.6069646.20.1173
500253124.12074.12020.6069652.40.1200
500253332.95142.95120.6669644.40.1157
500253302.95172.95120.6669648.00.1170
500253182.951192.95120.6669558.80.1227
503.6255154.13544.13520.6870346.50.1164
550279154.32144.32121.6076750.80.1066
550279124.32174.32121.6076457.60.1091
550279333.09643.09621.6776748.10.1051
550279303.09673.09621.6776652.10.1063
550279243.096133.09621.6776557.60.1088
550279183.096193.09621.6776564.30.1115
Conductor SizeNo. and Diameter of WiresNominal Outside DiameterMass per Unit LengthRated
strength
Nominal DC Resistance at 20℃
MCM(AWG)mm²AluminiumAlloy
No.mmNo.mmmmkg/kmKNΩ/km
587.2298154.46544.46522.3382054.30.0998
600304154.51344.51322.5683655.40.0977
600304124.51374.51322.5683562.90.1000
600304333.23343.23322.6383552.40.0964
600304303.23373.23322.6383656.80.0975
600304243.233133.23322.6383462.80.0998
600304183.233193.23322.6383370.10.1022
649.5329183.365193.36523.5690573.80.0944
650329333.36643.36623.5690556.30.0889
650329303.36673.36623.5690660.80.0899
650329243.366133.36623.5690566.60.0921
650329183.366193.36623.5690373.80.0943
653.1331124.70974.70923.5591168.50.0918
700355333.49343.49324.4597560.70.0826
700355303.49373.49324.4597565.50.0835
700355243.493133.49324.4597371.80.0855
700355183.493193.49324.4597379.50.0876
739.8375183.592193.59225.14103183.50.0828
750380333.61743.61725.32104564.00.0770
750380303.61773.61725.32104569.20.0779
750380243.617133.61725.32104576.20.0797
750380183.617193.61725.32104384.70.0817
800405333.73443.73426.14111468.20.0722
800405303.73473.73426.14111473.80.0731
800405243.734133.73426.14111381.20.0748
800405183.734193.73426.14111390.30.0766
850431333.85143.85126.96118571.30.0679
850431303.85173.85126.96118577.30.0687
850431243.851133.85126.96118485.40.0703
850431183.851193.85126.96118395.30.0721
853.7433243.858133.85827.01119185.80.0701
853.7433303.85873.85827.01119277.60.0685
900456333.96243.96227.73125575.50.0642
900456303.96273.96227.73125481.90.0649
900456243.962133.96227.73125390.50.0665

Conductor SizeNo. and Diameter of WiresNominal Outside DiameterMass per Unit LengthRated
strength
Nominal DC Resistance at 20℃
MCM(AWG)mm²AluminiumAlloy
No.mmNo.mmmmkg/kmKNΩ/km
900456183.962193.96227.7312531010.0681
927.2470244.021134.02128.15129493.20.0645
950481334.06944.06928.48132379.70.0608
950481304.06974.06928.48132386.40.0615
950481244.069134.06928.48132195.40.0630
950481184.069194.06928.4813211060.0645
1000507334.17644.17629.23139483.90.0578
1000507304.17674.17629.231393910.0584
1000507244.176134.17629.2313931010.0598
1000507184.176194.17629.2313911120.0613
1000507543.25173.25129.26139387.90.0579
1000507483.251133.25129.26139394.10.0587
1000507423.251193.25129.2613911020.0595
1000507333.251283.25129.2613911100.0608
1024.5519244.227134.22729.5914301030.0584
1024.5519304.22774.22729.59143193.20.0570
1080.6548244.341134.34130.3915081090.0554
1080.6548184.341194.34130.3915061210.0567
1100557334.37944.37930.65153292.30.0525
1100557304.37974.37930.6515331000.0531
1100557244.379134.37930.6515311110.0544
1100557184.379194.37930.6515301230.0557
1100557543.41173.41130.70153495.90.0526
1100557483.411133.41130.7015331020.0533
1100557423.411193.41130.7015311100.0541
1100557333.411283.41130.7015311190.0553
1109562244.397134.39730.7815471110.0540
1109562304.39774.39730.7815491010.0527
1172594184.521194.52131.6416341310.0523
1172594304.52174.52131.6416371070.0499
1198607244.570134.5731.9916721200.0499
1198607304.57074.5731.9916731090.0488
1200608334.57544.57532.0216731010.0481
1200608304.57574.57532.0216721090.0487
1200608244.575134.57532.0216711210.0498
Conductor SizeNo. and Diameter of WiresNominal Outside DiameterMass per Unit LengthRated
strength
Nominal DC Resistance at 20℃
MCM(AWG)mm²AluminiumAlloy
No.mmNo.mmmmkg/kmKNΩ/km
1200608184.575194.57532.0216691350.0511
1200608543.56473.56432.0816731040.0481
1200608483.564133.56432.0816731100.0488
1200608423.564193.56432.0816721190.0495
1200608333.564283.56432.0816711280.0506
1250633334.66944.66932.7017421050.0462
1250633304.66974.66932.7017411140.0467
1250633244.669134.66932.7017411260.0479
1250633184.669194.66932.7017381400.0490
1250633543.63573.63532.7217411070.0463
1250633483.635133.63532.7217401140.0469
1250633423.635193.63532.7217391240.0476
1250633333.635283.63532.7217381330.0487
1277647423.675193.67533.0817821260.0466
1277647543.67573.67533.0817841100.0453
1300659304.76074.76033.3218101180.0450
1300659244.760134.76033.3218091310.0460
1300659184.760194.76033.3218081460.0472
1300659334.76044.76033.3218111090.0445
1300659543.70873.70833.3718121120.0445
1300659483.708133.70833.3718111190.0451
1300659423.708193.70833.3718111290.0458
1300659333.708283.70833.3718091390.0468
1361.5690543.79573.79534.1519021170.0425
1400709543.84873.84834.6319521180.0413
1400709483.848133.84834.6319501260.0419
1400709423.848193.84834.6319501370.0425
1400709333.848283.84834.6319481480.0434
1500760543.98373.98335.8520901270.0385
1500760483.983133.98335.8520891350.0391
1500760423.983193.98335.8520891470.0397
1500760333.983283.98335.8520861590.0405
1534.4777424.028194.02836.2621411500.0388
1600811544.11574.11537.0422311350.0361
1600811484.115134.11537.0422301450.0366

Conductor SizeNo. and Diameter of WiresNominal Outside DiameterMass per Unit LengthRated
strength
Nominal DC Resistance at 20℃
MCM(AWG)mm²AluminiumAlloy
No.mmNo.mmmmkg/kmKNΩ/km
1600811424.115194.11537.0422291570.0372
1600811334.115284.11537.0422281600.0380
1700861544.23974.23938.1523691430.0340
1700861484.239134.23938.1523671530.0345
1700861424.239194.23938.1523671660.0350
1700861334.239284.23938.1523641800.0358
1703863484.244134.24438.2023781540.0344
1750887544.30374.30338.7324391480.0330
1750887484.303134.30338.7324371580.0335
1750887424.303194.30338.7324381710.0340
1750887334.303284.30338.7324361860.0347
1798911424.361194.36139.2525091760.0331
1800912544.36474.36439.2825101520.0321
1800912484.364134.36439.2825081630.0326
1800912424.364194.36439.2825071760.0330
1800912334.364284.36439.2825051910.0338
1900963544.48374.48340.3526491600.0304
1900963484.483134.48340.3526481720.0309
1900963424.483194.48340.3526461860.0313
1900963334.483284.48340.3526442010.0320
1933979424.522194.52240.6926981890.0308
20001013544.60074.60041.4027881690.0289
20001013484.600134.60041.4027881810.0293
20001013424.600194.60041.4027861960.0297
20001013334.600284.60041.4027832120.0304
20001013723.764193.76441.4027851820.0293
20001013633.764283.76441.4027831930.0297
20001013543.764373.76441.4027842070.0302
22501140723.993193.99343.9231642020.0263
22501140633.993283.99343.9231632150.0267
22501140543.993373.99343.9231592310.0271
23381185424.973194.97344.7532952290.0257
23381185484.973134.97344.7532972110.0253
24931263544.204374.20446.2535122560.0244
24931263724.204194.20446.2535152240.0237
Conductor SizeNo. and Diameter of WiresNominal Outside DiameterMass per Unit LengthRated
strength
Nominal DC Resistance at 20℃
MCM(AWG)mm²AluminiumAlloy
No.mmNo.mmmmkg/kmKNΩ/km
25001267724.209194.20946.3035152250.0237
25001267634.209284.20946.3035162390.0240
25001267544.209374.20946.3035082570.0244
27501393724.415194.41548.5638712470.0215
27501393634.415284.41548.5638602630.0218
27501393544.415374.41548.5638672820.0222
30001520724.613194.61350.7442212700.0197
30001520634.613284.61350.7442162870.0200
30001520544.613374.61350.7442183080.0203
ACAR (JL/LHA2, JL1/LHA2)
Code
Number
AreaNo. of WiresWire DiameterDiameterLinear MassRated StrengthD.C. Resistance
at 20℃





AL.AlloyTotalAL.AlloyAL.AlloyCoreCond.JL/LHA2JL1/LHA2
mm²
mmmmkg/kmkNΩ/km


25/2024.318.242.5432.782.78—8.34116.69.230.71550.7119



40/3038.328.767.0433.493.49—10.5183.714.360.45400.4517




60/4560.845.6106434.404.40—13.2292.022.520.28560.2842




80/5083.148.51321272.972.978.9114.9362.427.720.22980.2286




105/6010662.11681273.363.3610.116.8463.834.950.17960.1786




130/14013213927018193.053.0515.321.4744.360.600.11420.1137




135/8013478.12121273.773.7711.318.9583.943.330.14260.1419




135/14013414227618193.083.0815.421.6760.261.800.11220.1117




135/14513614327918193.103.1015.521.7770.162.610.11070.1103




165/17016317333618193.403.4017.023.8926.475.310.09210.0917




165/17516517534018193.423.4217.123.9937.376.200.09100.0906




170/9516797.42641274.214.2112.621.1729.654.040.11460.1140




210/22020721942618193.833.8319.226.81175.594.530.07260.0722




210/23021923245118193.943.9419.727.61244.0100.00.06860.0683




235/25023825148818194.104.1020.528.71347.1108.30.06330.0630




260/27526427854218194.324.3221.630.21495.6120.30.05700.0568




265/6026361.33243073.343.3410.023.4894.260.560.09130.0906




270/42027242069224373.803.8026.634.21910.5161.10.04540.0452




307/47030647277824374.034.0328.236.32148.7181.20.04030.0402




335/8033578.14133073.773.7711.326.41139.375.480.07160.0711





Code
Number
AreaNo. of WiresWire DiameterDiameterLinear MassRated StrengthD.C. Resistance
at 20℃





AL.AlloyTotalAL.AlloyAL.AlloyCoreCond.JL/LHA2JL1/LHA2
mm²
mmmmkg/kmkNΩ/km


345/53034553287824374.284.2830.038.52423.6204.40.03580.0356



365/16536616553142193.333.3316.730.01467.2106.70.05670.0564




375/8537587.54633073.993.9912.027.91276.284.550.06390.0635




415/9541897.45153074.214.2112.629.51420.894.130.05740.0570




455/20545620766342193.723.7218.633.51831.0130.90.04540.0452




465/1104691095783074.464.4613.431.21594.5105.60.05120.0508




465/21046421067442193.753.7518.833.81860.6133.00.04470.0444




505/6550565.45705473.453.4510.431.11575.2101.60.05140.0511




515/23051523374842193.953.9519.835.62064.4147.60.04030.0401




535/24053323977242374.022.8720.136.22135.0152.40.03900.0388




570/39056838995754373.663.6625.640.32646.7190.00.03190.0317




580/26057926284142194.194.1921.037.72322.9166.10.03580.0356




630/430632433106554373.863.8627.042.52943.8211.30.02870.0285




650/29565029494442194.444.4422.240.02608.3186.50.03190.0317




665/30066830196942374.503.2222.540.52679.0191.30.03110.0309




705/485709486119654374.094.0928.645.03305.1237.30.02550.0254




745/335747336108342374.763.4023.842.82994.2213.70.02780.0277




790/540792542133454374.324.3230.247.53687.3264.70.02290.0228




800/550803550135254374.354.3530.547.93738.7268.40.02260.0225




820/215817215103272193.803.8019.041.82852.9181.50.02880.0286




915/240914241115572194.024.0220.144.23192.8203.10.02570.0256




1020/2701021270129172194.254.2521.346.83568.6227.00.02300.0229




1145/3001145302144772194.504.5022.549.54000.8254.50.02050.0204




ACAR (JL2/LHA2,JL3/LHA2)
Code
Number
AreaNo. of wiresWire DiameterDiameterLinear MassRated StrengthD.C. Resistance
at 20℃





AL.AlloyTotalAL.AlloyAL.AlloyCoreCondJL2/LHA2JL3/LHA2
mm²
mmmmkg/kmkNΩ/km


25/2024.318.242.5432.782.78—8.34116.69.230.70840.7050



40/3038.328.767.0433.493.49—10.5183.714.360.44950.4473




60/4560.845.6106434.404.40—13.2292.022.520.28280.2814




80/5083.148.51321272.972.978.9114.9362.427.720.22740.2262




105/6010662.11681273.363.3610.116.8463.834.950.17770.1767




130/14013213927018193.053.0515.321.4744.360.600.11330.1128




135/14513614327918193.103.1015.521.7770.162.610.10980.1093





Code
Number
AreaNo. of wiresWire DiameterDiameterLinear MassRated StrengthD.C. Resistance
at 20℃





AL.AlloyTotalAL.AlloyAL.AlloyCoreCondJL2/LHA2JL3/LHA2
mm²
mmmmkg/kmkNΩ/km


165/17016317333618193.403.4017.023.8926.475.310.09130.0909



165/17516517534018193.423.4217.123.9937.376.200.09020.0898




170/9516797.42641274.214.2112.621.1729.654.040.11340.1128




210/22020721942618193.833.8319.226.81175.594.530.07190.0716




210/23021923245118193.943.9419.727.61244.0100.00.06800.0677




235/25023825148818194.104.1020.528.71347.1108.30.06280.0625




260/27526427854218194.324.3221.630.21495.6120.30.05650.0563




265/6026361.33243073.343.3410.023.4894.260.560.09000.0894




270/42027242069224373.803.8026.634.21910.5161.10.04500.0449




307/47030647277824374.034.0328.236.32148.7181.20.04010.0399




335/8033578.14133073.773.7711.326.41139.375.480.07070.0702




345/53034553287824374.284.2830.038.52423.6204.40.03550.0354




365/16536616553142193.333.3316.730.01467.2106.70.05600.0557




375/8537587.54633073.993.9912.027.91276.284.550.06310.0627




415/9541897.45153074.214.2112.629.51420.894.130.05670.0563




455/20545620766342193.723.7218.633.51831.0130.90.04490.0446




465/1104691095783074.464.4613.431.21594.5105.60.05050.0502




465/21046421067442193.753.7518.833.81860.6133.00.04420.0439




505/6550565.45705473.453.4510.431.11575.2101.60.05070.0503




515/23051523374842193.953.9519.835.62064.4147.60.03980.0396




535/24053323977242374.022.8720.136.22135.0152.40.03860.0383




570/39056838995754373.663.6625.640.32646.7190.00.03160.0314




580/26057926284142194.194.1921.037.72322.9166.10.03540.0352




630/430632433106554373.863.8627.042.52943.8211.30.02840.0282




650/29565029494442194.444.4422.240.02608.3186.50.03150.0313




665/30066830196942374.503.2222.540.52679.0191.30.03070.0306




705/485709486119654374.094.0928.645.03305.1237.30.02530.0252




745/335747336108342374.763.4023.842.82994.2213.70.02750.0273




790/540792542133454374.324.3230.247.53687.3264.70.02270.0226




800/550803550135254374.354.3530.547.93738.7268.40.02240.0222




820/215817215103272193.803.8019.041.82852.9181.50.02840.0282




915/240914241115572194.024.0220.144.23192.8203.10.02540.0252




1020/2701021270129172194.254.2521.346.83568.6227.00.02270.0226




1145/3001145302144772194.504.5022.549.54000.8254.50.02030.0201




Product Display

拼图_美图设计室

Qualification Certificate

  • 润邦线缆有限公司-智能制造管理体系认证证书-1
  • 润邦线缆有限公司-碳足迹认证证书
  • 润邦线缆有限公司-绿色设计产品管理体系认证证书-1
  • 润邦线缆有限公司-绿色供应链管理体系认证证书-1
  • 润邦线缆有限公司-绿色工厂认证证书-1
  • 润邦线缆2026.06.01一种可清障的高压架空线
  • 润邦2023208745394一种多芯分支组合电缆
  • 润邦2022228563977一种变电站电力输送用电缆

Factory Showcase

  • Z01231
  • Z01238
  • Z01237
  • Z01236
  • Z01233
  • DSC09918

FAQ

01 — What specifications are available for this cable?

We offer different conductor sizes, insulation materials, voltage ratings, core configurations and other specifications according to product type and application requirements. Please contact us for the detailed product specification sheet.

 

02 — Can this cable be customized?

Yes. Cable specifications can be customized based on your application, installation environment and project requirements. Our team can assist with conductor size, insulation, sheath, voltage rating, color, length and other requirements.

 

03 — What standards does this cable comply with?

Our cable products can be manufactured according to applicable international and regional standards depending on the product and customer requirements. Please confirm the required standard with our sales team before placing an order.


04 — Can you provide samples before bulk orders?

Yes. Samples may be available for evaluation depending on the product type and specifications. Please contact us with your required model and specifications so we can confirm sample availability.

 

05 — What is the minimum order quantity?

MOQ depends on the cable type, specifications and production requirements. Please contact us with your required quantity and specifications for a specific quotation.

 

06 — How long is the production lead time?

Production lead time depends on product specifications, order quantity and current production schedules. We will confirm the estimated delivery time when providing the quotation.

Contact Us

Submit

Related products

DC001

DC001

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC003

DC003

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC004

DC004

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC005

DC005

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC006

DC006

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC0011

DC0011

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC0013

DC0013

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

DC0018

DC0018

A cable is a device for transmitting electrical energy or signals, consisting of one or more mutually insulated conductors enclosed within a protective insulating layer. Typically formed by twisting together several wires or groups of wires, it features a design that conducts electricity internally while providing external insulation, and is widely used in power transmission, information and communication, industrial control, and the interconnection of various electronic devices.

High Voltage Cable

High Voltage Cable

High voltage cables suitable for a variety of applications, from powering homes and businesses to large-scale industrial operations. Knowing how these cables work and understanding their various components is essential for anyone looking to install or maintain them.

YSLY Control Cable

YSLY Control Cable

PVC Insualted Control Cable Voltage Rating: 300/500V Conductor: soft annealed copper,class 5 Insulation: PVC Sheath: PVC

Solar Cables

Solar Cables

Widely used for electrical installation of indoor and outdoor solar energy equipment.

6 / 20